СКУ: TM251MDESE
SCHNEIDER ELECTRIC Logic controller, Modicon M251, 2x Ethernet
-
Brand
Schneider Electric
-
Supporting protocol for SERCOS
FALSE
-
SIL according to IEC 61508
EV000494
-
Performance level according to EN ISO 13849-1
EV000494
-
Radio standard GPRS
FALSE
-
Height
90
-
Supporting protocol for INTERBUS-Safety
FALSE
-
Supporting protocol for AS-Interface Safety at Work
FALSE
-
Radio standard GSM
FALSE
-
Explosion safety category for dust
EV000494
-
Radio standard UMTS
FALSE
-
Explosion safety category for gas
EV000494
-
Supporting protocol for DeviceNet Safety
FALSE
-
Supporting protocol for Foundation Fieldbus
FALSE
-
Supporting protocol for SafetyBUS p
FALSE
-
Voltage type of supply voltage
EV000461
-
Supporting protocol for PROFINET CBA
FALSE
-
Supporting protocol for PROFINET IO
FALSE
-
Supporting protocol for PROFIsafe
FALSE
-
Supporting protocol for ASI
FALSE
-
Radio standard Bluetooth
FALSE
-
Supporting protocol for PROFIBUS
FALSE
-
Appendant operation agent (Ex ia)
FALSE
-
Radio standard Wi-Fi 802.11
FALSE
-
Front built-in possible
FALSE
-
Supporting protocol for KNX
FALSE
-
Supporting protocol for CAN
FALSE
-
Appendant operation agent (Ex ib)
FALSE
-
Supporting protocol for INTERBUS
FALSE
-
IO link master
FALSE
-
Supporting protocol for DeviceNet
FALSE
-
Suitable for safety functions
FALSE
-
Supporting protocol for Data-Highway
FALSE
-
Rack-assembly possible
FALSE
-
Supporting protocol for LON
FALSE
-
Supporting protocol for SUCONET
FALSE
-
Rail mounting possible
TRUE
-
Supporting protocol for other bus systems
FALSE
-
With display
FALSE
-
With optical interface
FALSE
-
System accessory
FALSE
-
Depth
95
-
Number of HW-interfaces parallel
-
Number of interfaces PROFINET
-
Number of HW-interfaces other
-
Number of HW-interfaces Wireless
-
Supporting protocol for EtherNet/IP
TRUE
-
Supporting protocol for TCP/IP
TRUE
-
Supporting protocol for Modbus
TRUE
-
Number of HW-interfaces RS-485
2
-
Number of HW-interfaces RS-232
2
-
Number of HW-interfaces RS-422
-
Wall mounting/direct mounting
TRUE
-
Number of HW-interfaces industrial Ethernet
1
-
Number of analogue inputs
-
Number of analogue outputs
-
Redundancy
FALSE
-
Supporting protocol for IEC 61850 Ethernet
FALSE
-
Supply voltage DC
19.2
-
Width
150
-
Number of HW-interfaces USB
1
-
Supporting protocol for IEC 60870
FALSE
-
Supporting protocol for DNP3
FALSE
-
Additional program memory possible
TRUE
-
Model
EV002153
-
Long-Term Evolution (LTE)
FALSE
-
Number of digital inputs
14
-
Number of relay outputs
-
Number of digital outputs
10
-
Max. number of time switches
-
Type of memory
EV009358
-
Memory size
64000
-
Processing time (1K, binary operation)
0.022
Analog I/O expansion block, Modicon TM7, IP67, 4 TC inputs, M12 connector