СКУ: LV434022
Сензор PowerTag NSX - 630 A - 3P
-
Brand
Schneider Electric
-
Type of electric connection
EV000415
-
Supporting protocol for SERCOS
FALSE
-
SIL according to IEC 61508
EV000494
-
Radio standard GPRS
FALSE
-
Fieldbus connection over separate bus coupler possible
FALSE
-
Supporting protocol for INTERBUS-Safety
FALSE
-
Supporting protocol for AS-Interface Safety at Work
FALSE
-
Radio standard GSM
FALSE
-
Radio standard UMTS
FALSE
-
Supporting protocol for DeviceNet Safety
FALSE
-
Supporting protocol for Foundation Fieldbus
FALSE
-
Supporting protocol for SafetyBUS p
FALSE
-
Voltage type of supply voltage
EV000461
-
Supporting protocol for PROFINET CBA
FALSE
-
Supporting protocol for PROFINET IO
FALSE
-
Supporting protocol for PROFIsafe
FALSE
-
Supporting protocol for ASI
FALSE
-
Radio standard Bluetooth
FALSE
-
Supporting protocol for PROFIBUS
FALSE
-
Appendant operation agent (Ex ia)
FALSE
-
Radio standard Wi-Fi 802.11
FALSE
-
Supporting protocol for TCP/IP
FALSE
-
Front built-in possible
FALSE
-
Supporting protocol for KNX
FALSE
-
Supporting protocol for CAN
FALSE
-
Appendant operation agent (Ex ib)
FALSE
-
Supporting protocol for INTERBUS
FALSE
-
Supporting protocol for DeviceNet
FALSE
-
Supporting protocol for Modbus
FALSE
-
Suitable for safety functions
FALSE
-
Supporting protocol for Data-Highway
FALSE
-
Rack-assembly possible
FALSE
-
Supporting protocol for LON
FALSE
-
Supporting protocol for SUCONET
FALSE
-
Wall mounting/direct mounting
FALSE
-
Rail mounting possible
TRUE
-
Supporting protocol for other bus systems
FALSE
-
Analogue outputs configurable
FALSE
-
Analogue input, resistor
FALSE
-
With optical interface
FALSE
-
System accessory
FALSE
-
Digital outputs configurable
TRUE
-
Analogue output, voltage
FALSE
-
Analogue output signal configurable
FALSE
-
Analogue output, current
FALSE
-
Type of digital output
EV000154
-
Analogue input, current
FALSE
-
Analogue input, voltage
FALSE
-
Number of HW-interfaces parallel
-
Number of interfaces PROFINET
-
Number of HW-interfaces serial TTY
-
Number of HW-interfaces Wireless
-
Supporting protocol for EtherNet/IP
TRUE
-
IO link master
TRUE
-
Number of HW-interfaces RS-422
-
Number of HW-interfaces industrial Ethernet
-
Degree of protection (IP)
EV006409
-
Analogue inputs configurable
TRUE
-
Number of analogue outputs
-
Number of HW-interfaces USB
-
Number of HW-interfaces RS-485
-
Number of HW-interfaces RS-232
-
Number of analogue inputs
1
-
Analogue input, resistor temperature
TRUE
-
Number of HW-interfaces other
2
-
Analogue input, thermocouple
TRUE
-
Digital inputs configurable
TRUE
-
Analogue input signal configurable
TRUE
-
Permitted voltage at input
19.8
-
Type of voltage (input voltage)
EV000461
-
Time delay at signal exchange
-
Height
116
-
Width
71.7
-
Depth
70.6
-
Short-circuit protection, digital outputs available
TRUE
-
Input current at signal 1
6.1
-
Type of output voltage
EV000460
-
Number of digital outputs
3
-
Number of digital inputs
6
-
Supply voltage DC
19.2
-
Output current at digital output
5
-
Output voltage at digital output
250
This I/O module is an Input/Output application module and it is part of EnerlinX communication system. This I/O module is compatible with Masterpact, Compact and PowerPact devices. It is used for protection, circuit breaker control, motor control, energy management and monitoring applications. It provides six digital inputs, three digital outputs and one analog input. It is equipped on the top with one 24VDC screw clamp terminal block and one terminal block for the 6 digital inputs. There are two RJ45 sockets on the bottom for ULP, and 4 terminal blocks for the digital outputs and analog input. The I/O module is a DIN rail mounting device and its dimensions are 72mm x 116mm x 71mm. The protection degree is IP4x on the front face and IP2x on the connectors. The I/O module is entirely part of the EcoStruxure Power architecture and Ethernet ready smart panels. The I/O module can be configured and updated (firmware) using EcoStruxure Power Commission software.
Similar
Products
Recently viewed