СКУ: ATV12H018M3
Честотен регулатор ATV12 - 0.18kW - 0.25hp - 200..240V - 3ph
-
Brand
Schneider Electric
-
Degree of protection (IP)
EV006405
-
Supporting protocol for SERCOS
FALSE
-
Supporting protocol for INTERBUS-Safety
FALSE
-
Supporting protocol for AS-Interface Safety at Work
FALSE
-
Supporting protocol for DeviceNet Safety
FALSE
-
Supporting protocol for EtherNet/IP
FALSE
-
Supporting protocol for Foundation Fieldbus
FALSE
-
Supporting protocol for SafetyBUS p
FALSE
-
Supporting protocol for PROFINET CBA
FALSE
-
Supporting protocol for PROFINET IO
FALSE
-
Supporting protocol for PROFIsafe
FALSE
-
Supporting protocol for ASI
FALSE
-
Supporting protocol for PROFIBUS
FALSE
-
Supporting protocol for TCP/IP
FALSE
-
Supporting protocol for KNX
FALSE
-
Supporting protocol for CAN
FALSE
-
Supporting protocol for INTERBUS
FALSE
-
Supporting protocol for DeviceNet
FALSE
-
Supporting protocol for Data-Highway
FALSE
-
Supporting protocol for LON
FALSE
-
Supporting protocol for SUCONET
FALSE
-
Width
105
-
Supporting protocol for other bus systems
FALSE
-
With control element
TRUE
-
With optical interface
FALSE
-
Number of HW-interfaces parallel
-
Number of interfaces PROFINET
-
Number of HW-interfaces serial TTY
-
Supporting protocol for Modbus
TRUE
-
Number of HW-interfaces RS-422
-
Number of HW-interfaces RS-485
1
-
Number of HW-interfaces industrial Ethernet
-
Number of analogue outputs
1
-
Number of HW-interfaces USB
-
Number of HW-interfaces RS-232
-
Number of digital outputs
1
-
Number of analogue inputs
1
-
Number of digital inputs
4
-
Height
142
-
Supporting protocol for BACnet
FALSE
-
Type of converter
EV009484
-
Mains frequency
EV008015
-
Number of phases output
EV000069
-
Relative symmetric net voltage tolerance
10
-
Relative symmetric net frequency tolerance
5
-
Integrated breaking resistance
FALSE
-
Application in industrial area permitted
TRUE
-
4-quadrant operation possible
FALSE
-
Number of HW-interfaces other
8
-
Max. output frequency
400
-
With PC connection
TRUE
-
Number of phases input
EV000599
-
Application in domestic- and commercial area permitted
TRUE
-
Max. output voltage
230
-
Depth
156.2
-
Mains voltage
200
-
Max. output at quadratic load at rated output voltage
1.5
-
Max. output at linear load at rated output voltage
1.5
-
Nominal output current I2N
7.5
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.