СКУ: ATV630U30N4
Честотен регулатор ATV630 IP21 3KW 400V/480V
-
Brand
Schneider Electric
-
Supporting protocol for SERCOS
FALSE
-
Supporting protocol for INTERBUS-Safety
FALSE
-
Supporting protocol for AS-Interface Safety at Work
FALSE
-
Supporting protocol for DeviceNet Safety
FALSE
-
Supporting protocol for Foundation Fieldbus
FALSE
-
Supporting protocol for SafetyBUS p
FALSE
-
Supporting protocol for PROFINET CBA
FALSE
-
Supporting protocol for PROFINET IO
FALSE
-
Supporting protocol for PROFIsafe
FALSE
-
Supporting protocol for ASI
FALSE
-
Supporting protocol for KNX
FALSE
-
Supporting protocol for INTERBUS
FALSE
-
Supporting protocol for Data-Highway
FALSE
-
Supporting protocol for LON
FALSE
-
Supporting protocol for SUCONET
FALSE
-
Supporting protocol for other bus systems
FALSE
-
Number of HW-interfaces parallel
-
Number of interfaces PROFINET
-
Number of HW-interfaces other
-
Number of HW-interfaces serial TTY
-
Supporting protocol for EtherNet/IP
TRUE
-
Supporting protocol for TCP/IP
TRUE
-
Supporting protocol for Modbus
TRUE
-
Number of HW-interfaces RS-485
2
-
Supporting protocol for CAN
TRUE
-
Number of HW-interfaces RS-422
-
Number of HW-interfaces industrial Ethernet
-
Number of analogue outputs
2
-
Number of digital outputs
-
Number of HW-interfaces USB
-
Number of HW-interfaces RS-232
-
With control element
FALSE
-
Number of digital inputs
6
-
Height
630
-
With PC connection
FALSE
-
Degree of protection (IP)
EV006404
-
Supporting protocol for BACnet
FALSE
-
With optical interface
TRUE
-
Supporting protocol for PROFIBUS
TRUE
-
Supporting protocol for DeviceNet
TRUE
-
Type of converter
EV009484
-
Mains voltage
500
-
Max. output frequency
500
-
Mains frequency
EV008015
-
Number of phases input
EV000069
-
Relative symmetric net voltage tolerance
10
-
Relative symmetric net frequency tolerance
5
-
Application in domestic- and commercial area permitted
FALSE
-
Integrated breaking resistance
FALSE
-
4-quadrant operation possible
FALSE
-
Max. output voltage
690
-
Max. output at quadratic load at rated output voltage
75
-
Max. output at linear load at rated output voltage
75
-
Number of analogue inputs
3
-
Width
331
-
Depth
297
-
Number of phases output
EV000600
-
Application in industrial area permitted
FALSE
-
Nominal output current I2N
83
This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 200V to 240V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 1.5kW/2HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 0.75kW / 1hp for applications requiring significant overload (up to 150%). It weighs 4.3kg and its dimensions are 144mm (width) x 203mm (depth) x 350mm (height). This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. This product is certified by ATEX INERIS, ATEX zone 2/22, CE, CSA, DNV-GL, UL and TUV. It meets UL 508C, EN/IEC 61800-3, EN/IEC 61800-5-1 and IEC 61000-3-12 standards. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
Similar