СКУ: ATV12H075M2
SCHNEIDER ELECTRIC Variable speed drive ATV12 - 0.75kW, 1PH, 200..240V
-
Brand
Schneider Electric
-
Degree of protection (IP)
EV006405
-
Supporting protocol for SERCOS
FALSE
-
Supporting protocol for INTERBUS-Safety
FALSE
-
Supporting protocol for AS-Interface Safety at Work
FALSE
-
Supporting protocol for DeviceNet Safety
FALSE
-
Supporting protocol for EtherNet/IP
FALSE
-
Supporting protocol for Foundation Fieldbus
FALSE
-
Supporting protocol for SafetyBUS p
FALSE
-
Supporting protocol for PROFINET CBA
FALSE
-
Supporting protocol for PROFINET IO
FALSE
-
Supporting protocol for PROFIsafe
FALSE
-
Supporting protocol for ASI
FALSE
-
Supporting protocol for PROFIBUS
FALSE
-
Supporting protocol for TCP/IP
FALSE
-
Supporting protocol for KNX
FALSE
-
Supporting protocol for CAN
FALSE
-
Supporting protocol for INTERBUS
FALSE
-
Supporting protocol for DeviceNet
FALSE
-
Supporting protocol for Data-Highway
FALSE
-
Supporting protocol for LON
FALSE
-
Supporting protocol for SUCONET
FALSE
-
Supporting protocol for other bus systems
FALSE
-
Width
72
-
With control element
TRUE
-
With optical interface
FALSE
-
Number of HW-interfaces parallel
-
Number of interfaces PROFINET
-
Number of HW-interfaces serial TTY
-
Supporting protocol for Modbus
TRUE
-
Number of HW-interfaces RS-422
-
Number of HW-interfaces RS-485
1
-
Number of HW-interfaces industrial Ethernet
-
Number of analogue outputs
1
-
Number of HW-interfaces USB
-
Number of HW-interfaces RS-232
-
Number of digital outputs
1
-
Number of analogue inputs
1
-
Number of digital inputs
4
-
Supporting protocol for BACnet
FALSE
-
Type of converter
EV009484
-
Mains frequency
EV008015
-
Number of phases input
EV000069
-
Number of phases output
EV000069
-
Relative symmetric net voltage tolerance
10
-
Relative symmetric net frequency tolerance
5
-
Integrated breaking resistance
FALSE
-
Application in industrial area permitted
TRUE
-
4-quadrant operation possible
FALSE
-
Number of HW-interfaces other
8
-
Max. output frequency
400
-
Height
143
-
With PC connection
TRUE
-
Depth
1212
-
Max. output at quadratic load at rated output voltage
0.37
-
Max. output at linear load at rated output voltage
0.37
-
Application in domestic- and commercial area permitted
TRUE
-
Nominal output current I2N
2.4
-
Max. output voltage
230
-
Mains voltage
200
This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 18.5kW/25hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 15kW/20hp for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+/- 10 °) on a wall.