СКУ: LU9M1
SCHNEIDER ELECTRIC Control terminal block, reversing motor starter
-
Brand
Schneider Electric
-
Type of electrical connection of main circuit
EV000415
-
Rated operation power at AC-3, 400 V
18.5
-
Degree of protection (IP)
EV006405
-
Suitable for emergency stop
FALSE
-
Rated control supply voltage Us at AC 50HZ
24
-
Rated control supply voltage Us at AC 60HZ
24
-
Voltage type for actuating
EV000509
-
Rated control supply voltage Us at DC
24
-
Supporting protocol for SERCOS
FALSE
-
Supporting protocol for INTERBUS-Safety
FALSE
-
Supporting protocol for AS-Interface Safety at Work
FALSE
-
Supporting protocol for DeviceNet Safety
FALSE
-
Supporting protocol for EtherNet/IP
FALSE
-
Supporting protocol for Foundation Fieldbus
FALSE
-
Supporting protocol for SafetyBUS p
FALSE
-
Supporting protocol for PROFINET CBA
FALSE
-
Supporting protocol for PROFINET IO
FALSE
-
Supporting protocol for PROFIsafe
FALSE
-
Supporting protocol for ASI
FALSE
-
Supporting protocol for PROFIBUS
FALSE
-
Supporting protocol for TCP/IP
FALSE
-
Supporting protocol for CAN
FALSE
-
Supporting protocol for INTERBUS
FALSE
-
Supporting protocol for DeviceNet
FALSE
-
Supporting protocol for Modbus
FALSE
-
Supporting protocol for Data-Highway
FALSE
-
Supporting protocol for LON
FALSE
-
Supporting protocol for SUCONET
FALSE
-
Number of auxiliary contacts as normally closed contact
1
-
Number of auxiliary contacts as normally open contact
1
-
Number of indicator lights
-
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000
-
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000
-
With transformer
FALSE
-
Ambient temperature, upper operating limit
70
-
External reset possible
FALSE
-
Type of electrical connection for auxiliary- and control current circuit
EV000415
-
Height
154
-
Number of command positions
3
-
Width
45
-
Coordination class according to IEC 60947-4-3
EV006627
-
Depth
126
-
Type of motor starter
EV004003
-
Rail mounting possible
TRUE
-
Supporting protocol for other bus systems
FALSE
-
With fuse
FALSE
-
With short-circuit release
TRUE
-
Rated conditional short-circuit current, type 2, 230 V
25000
-
Rated operation current Ie
38
-
Rated operation current at AC-3, 400 V
38
-
Rated conditional short-circuit current, type 2, 400 V
25000
-
Rated operation power at AC-3, 230 V, 3-phase
9
-
Rated power, 575 V, 60 Hz, 3-phase
18.5
-
Rated power, 460 V, 60 Hz, 3-phase
18.5
The LRE relay is a differential thermal overload relays for use with fuses or magnetic circuit-breakers. Its thermal setting range is 30-38A 50/60Hz and the tripping class is 10A conforming to IEC 60947-4-1. It can be direct mounted on Easy TeSys Control contactors with screw clamp terminals connection. It protects unbalanced loads and motors with 18.5kW at 400VAC. It provides manual or automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (CB scheme,CE,CCC,EAC) and Environmental compliant (RoHS/REACH).
Similar
Products
Recently viewed