СКУ: TPRVM001
интерфейс модул за напрежение, TeSys island, 690VAC 47-63 Hz, Изолиран превключващ вход за безопасно спиране
-
Brand
Schneider Electric
-
Degree of protection (IP)
EV006405
-
Supporting protocol for SERCOS
FALSE
-
SIL according to IEC 61508
EV000494
-
System accessory
TRUE
-
Performance level according to EN ISO 13849-1
EV000494
-
Radio standard GPRS
FALSE
-
Supporting protocol for INTERBUS-Safety
FALSE
-
Supporting protocol for AS-Interface Safety at Work
FALSE
-
Radio standard GSM
FALSE
-
Explosion safety category for dust
EV000494
-
Radio standard UMTS
FALSE
-
Explosion safety category for gas
EV000494
-
Supporting protocol for DeviceNet Safety
FALSE
-
Supporting protocol for EtherNet/IP
FALSE
-
Supporting protocol for Foundation Fieldbus
FALSE
-
Supporting protocol for SafetyBUS p
FALSE
-
Voltage type of supply voltage
EV000461
-
Supporting protocol for PROFINET CBA
FALSE
-
Supporting protocol for PROFINET IO
FALSE
-
Supporting protocol for PROFIsafe
FALSE
-
Supporting protocol for ASI
FALSE
-
Radio standard Bluetooth
FALSE
-
Supporting protocol for PROFIBUS
FALSE
-
Appendant operation agent (Ex ia)
FALSE
-
Radio standard Wi-Fi 802.11
FALSE
-
Supporting protocol for TCP/IP
FALSE
-
Front built-in possible
FALSE
-
Supporting protocol for KNX
FALSE
-
Supporting protocol for CAN
FALSE
-
Appendant operation agent (Ex ib)
FALSE
-
Supporting protocol for INTERBUS
FALSE
-
IO link master
FALSE
-
Supporting protocol for DeviceNet
FALSE
-
Supporting protocol for Modbus
FALSE
-
Suitable for safety functions
FALSE
-
Supporting protocol for Data-Highway
FALSE
-
Rack-assembly possible
FALSE
-
Supporting protocol for LON
FALSE
-
Supporting protocol for other bus systems
TRUE
-
Supporting protocol for SUCONET
FALSE
-
Wall mounting/direct mounting
FALSE
-
Rail mounting possible
TRUE
-
Analogue inputs configurable
FALSE
-
Width
25
-
Input, thermocouple
FALSE
-
Input signal, configurable
FALSE
-
Input, resistor
FALSE
-
Input, resistance thermometer
FALSE
-
Input, current
FALSE
-
Output signal configurable
FALSE
-
Input, voltage
TRUE
-
Output, voltage
FALSE
-
Output, current
FALSE
-
Depth
114
-
Type of electric connection
EV000414
-
Number of HW-interfaces other
2
-
Fieldbus connection over separate bus coupler possible
TRUE
-
Height
118
-
Supply voltage DC
20.4
-
Resolution of the analogue inputs
13
-
Number of analogue inputs
3
-
Number of analogue outputs
-
Number of HW-interfaces parallel
-
Number of interfaces PROFINET
-
Number of HW-interfaces serial TTY
-
Number of HW-interfaces USB
-
Number of HW-interfaces Wireless
-
Number of HW-interfaces RS-422
-
Number of HW-interfaces RS-485
-
Number of HW-interfaces industrial Ethernet
-
Number of HW-interfaces RS-232
TeSys island voltage interface module, 100-690V / 47-63Hz. Connected to a TPRBC bus coupler it measures the mains voltages powering the loads. It provides the voltage values for power and energy calculation, calculates the RMS values and phase sequence. Voltage measurement range 100-690 V +/- 5 %, phase frequency measurement range 47-63 Hz +/- 1 Hz in single phase or 3-phase systems. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).