СКУ: APDU10150ME
APC rPDU ADV ME 32A 230V 1PH
-
Brand
APC Brand
-
Colour
EV000206
-
Number of phases
3
-
Width
56
-
With fuse
FALSE
-
Supply voltage
230
-
Type of electric connection
EV000154
-
Mounting direction
EV001302
-
Cable length
3
-
With meter
TRUE
-
Mounting dimension (standardised)
EV000154
-
Ampere meter
TRUE
-
Evaluation
EV000154
-
Mains filter
FALSE
-
Control function
TRUE
-
Temperature measurement
FALSE
-
With mounting material
TRUE
-
SNMP
TRUE
-
With display
TRUE
-
With LED indication
TRUE
-
Depth
75
-
Switchable
FALSE
-
Number of C13 socket outlets
20
-
Electrical connection
EV000154
-
Length
75
-
Number of C19 socket outlets
20
-
Number of socket outlets with protective contact (SCHUKO)
20
-
Height
1490
-
Number of other socket outlets
-
Number of socket outlets with earth pin
-
Number of UK BS1363 sockets
-
Number of C20 socket outlets
-
Number of miniature circuit breakers
-
Number of height units
-
Number of socket outlets Swiss standard type 25
-
Number of socket outlets Swiss standard type 23
-
Number of socket outlets Swiss standard type 15
-
Number of socket outlets Swiss standard type 13
-
Mounting size
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.